Marksman Generator Manual

Wiring a Generator Cord Electrical Question: Should a generator cord have 3 or 4 wires? I am wiring a cord for my generator, would you suggest 3 conductor or 4 conductor cable? My Generator Specifications. I have an older gas powered generator and it is rated at: Voltage: 120/240. Amps: 41.7/20.8.

Fertigation and Chemigation like you’ve never had before!

How to disassemble and assemble a Marksman Repeater. Still photo video.Video has 10 second clips. If you need to, pause the video during a step and then cont. Marksman Air Pistols. Instruction Manual The generator is a potential source of electrical shock if misused. Do not expose the generator to moisture, rain or snow. DO not let the generator get wet, and do not operate it with wet hands.

Marksman will increase accuracy, reduce labor, and provide accurate records of every application. Marksman provides producers and retailers a line-up of features not common in most fertigation and chemigation systems.

Marksman Models

Marksman Hydra-Cell Pump

Flow Range: 15-180 GPH
Max Operating Pressure: 125 PSI
Power Options: 480VAC 3-Phase, 110VAC
Durable and robust industrial grade pump with years
of proven use in fertigation and chemigation
applications. Variable Frequency Drive (VFD) varies
motor speed to achieve desired application rate.

Marksman 12VDC Pump
Flow Range: 6-60 GPH
Max Operating Pressure: 50 PSI
Power Options: 480VAC 3-Phase, 110VAC, 12VDC
The economy solution for low pressure irrigation
systems. This system utilizes a 12VDC motor to drive
a diaphragm type pump. Works well in low pressure
irrigaton systems requiring low to medium application
rates.

Marksman No-Pump – Existing Injection Pump Control
Flow Range: Determined by Existing Pump
Max Operating Pressure: Lesser of 125 PSI or Maximum of Pump
Power Options: 480VAC
Add all the features of Marksman to your existing injection
metering pump–flow measurement and control, water
proportional control, shut down alarms and record keeping.
The Marksman for existing injection pumps provides VFD
controlled output of your current pump.

Marksman 550 Tank Skid with Hydra-Cell Pump
Flow Range: 15-180 GPH
Max Operating Pressure: 150 PSI
Power Options: 480VAC 3-Phase, 110VAC
550 gallon cone-bottom tank with variable speed propeller
agitation. Factory assembled with Marksman Hydra-Cell
system. Attach it to your trailer and it’s ready to go to the
field.

Features and Benefits
Marksman Generator Manual

Flow Measurement
All Marksman models utilize an electromagnetic flow meter to measure flow rate of fertilizer or water/chemical mixture. Electromagnetic meters have no moving parts to lodge, stick or wear. They precisely measure any electrically conductive liquid.

Flow Control
Set the desired flow rate (GPH) for your application and Marksman will control the pump output to achieve the desired rate for the entire application. Changes in product viscosity due to temperature variation, changes in head height of tank, and other variables that change flow rate through traditional metering pumps, are a thing of the past. Marksman ensures you get the exact application you need.

Water Proportional Control
Marksman changes the chemical or fertilizer flow rate in response to changes in water flow such as corner swing-arm systems. Marksman ensures the correct rate is applied regardless of the swing arm position.

Shut Down Alarms
Off Rate Alarm – If tank runs dry or the strainer plugs up and Marksman cannot achieve the desired flow rate, Marksman will automatically shut down. Utilize Marksman pivot shut down relay kit to stop the pivot as well.

• Low and High Pressure Alarm – If injection pressure drops below the minimum pressure set point, Marksman will shut down. Eliminates hours of costly and harmful spills due to a broken hose.
• Water Pressure Low and High Pressure Alarm – With optional water pressure sensor, Marksman will shut down based on too low or too high of water pressure.

Batch Mode
Inject set number of gallons, then turn off.

Marksman Generator Manual Generator

Auto Run on Power Up
At power up, Marksman will automatically start pumping. Automatically resume injection after power shut down due to load control. Useful in drip irrigation to apply set batch size to each zone of system.

Record Keeping – Data Logging


Record Keeping – Data Logging
Marksman keeps a complete record of every application. Every 10 minutes it logs an entry which includes field number, date, time, flow rate set point, actual flowrate, pressure and batch total. You will know when, where and how much was applied.

Regulatory and Supply Chain Reporting
This provides the necessary information you need for regulatory reporting. It also provides a record that can be used throughout a supply chain that wants to know more details of exactly how your product was grown, especially on fruits, vegetables and specialty crops. The log file is an Excel file that is downloaded directly from the Marksman via USB drive or directly from the cloud when equipped with remote connectivity.

Remote Connectivity


Checking fertigation/chemigation is now as easy as checking Twitter or Facebook…simply look at your phone! Get text message notification instantly if the application encounters a problem.

• Access via Any Web Browser – iPhone, Android, Desktop
• Monitor All System Information
• Marksman Reports System Status Every 10 Minutes
• Start/Stop Injection Pump
• Change Rate
• View Trend Chart
• See GPS Location of System on Map
• Download Application Log (Record Keeping)
• Battery Backup Allows Notification of Power Loss
• Text Message Notification of Start/Stop


Marksman Generator Manual

Marksman Generator Parts

Marksman Connectivity Via AgSense
Utilize your AgSense remote management system to monitor and control Marksman. Install an AgSense CropLink located next to the Marksman. Via the AgSense web portal you will be able to monitor:
• Marksman Flow Rate
• Marksman Pressure
• Water Pressure
• Water Flow Rate

Variable Rate Application
Marksman accepts prescription application maps from AgSense to vary
application rate based on pivot position.

Brochures & Manuals

Brochures
SureFire Marksman Brochure

Manuals
SureFire AC VFD Marksman Manual – Rev 9.24.18 (3612)
SureFire Marksman AC Variable Frequency Driven Pump manual_Rev 3.20.2017 (3612)
SureFire Marksman DC Pump manual_Rev 3.24.2017 (3624)
SureFire Marksman AC Variable Frequency Drive for Mechanical Metering Pump manual_(3651)
SureFire Marksman AgSense Compatibility Instructions_Rev 3.28.2017 (3652)